Course catalog
CEU courses
CEU courses for wastewater operators. Approval and credit differ by state, so the catalog below shows availability for one state at a time.
Each awards 1 hour · $19.00 USD each · All count toward Class 1-4 licenses.
Choose a subject to see its courses.
Safety20
Maintenance Chemicals: Grout, Paint and Fuel
Level 1
Workers sometimes handle grout, paint, or fuel without recognizing the chemical hazards or following proper safety rules, which can lead to exposure and regulatory trouble.
Approved for renewal creditRespond or Evacuate: The HAZWOPER Choice
Level 1
Confusion over when to handle hazardous spills in-house or evacuate can put employees at risk and violate safety rules.
Approved for renewal creditHazard Communication at a Treatment Plant
Level 1
Every chemical on site comes with a label and a safety data sheet you're expected to understand.
Approved for renewal creditWelding and Hot Work: The Fume You Did Not Choose
Level 1
Welding and hot work can create invisible fumes and gases like ozone or phosgene that put workers at risk and cause safety problems at the plant.
Approved for renewal creditClassifying Trench Soil: Two Tests, Five Traps
Level 1
Misclassifying trench soil can lead to unsafe excavations and trench collapses, risking serious injury and plant damage.
Approved for renewal creditPermit-Required Confined Space Entry
Level 1
Wet wells, manholes and tanks are where operators die, and too often it is the person who goes in to help.
Approved for renewal creditWastewater Operator Safety
Level 1
The hazards that kill operators: confined spaces, hydrogen sulfide and other bad atmospheres, stored energy, chemicals and biological exposure.
Approved for renewal creditHazard Assessment: What Changes the Answer
Level 2
Choosing the wrong respiratory protection or PPE in confined spaces can put operators at serious risk, especially with changing conditions and H2S levels.
Approved for renewal creditThe Bench Lab: Which OSHA Rule Covers It
Level 1
Wastewater bench labs often miss key OSHA rules that lead to unsafe conditions and compliance issues.
Approved for renewal creditLockout/Tagout for Pumps, Blowers and Mixers
Level 1
A pump, blower or mixer that restarts or turns over during maintenance can kill.
Approved for renewal creditFalls Into Tanks: The Trigger Is Not Four Feet
Level 1
Many operators think fall protection rules apply only above four feet, but falls near tanks and hazardous equipment can be just as dangerous.
Approved for renewal creditThe Safety Training Calendar: What Repeats
Level 1
Operators often miss or confuse safety training deadlines, risking noncompliance and unsafe work conditions.
Approved for renewal creditTrench Safety for Plant Crews: The 5-Foot Myth
Level 1
Many crews believe trenches under 5 feet deep don't need special safety measures, but this can lead to dangerous accidents.
Approved for renewal creditBloodborne Pathogens: What the Rule Covers
Level 1
Does the bloodborne pathogens rule apply to wastewater work? This hour covers where OSHA's standard applies and where it does not, how biological…
Approved for renewal creditHydrogen Sulfide: Four Numbers, One Ceiling
Level 1
Hydrogen sulfide has several exposure limits, and mixing them up can put an operator in danger.
Approved for renewal creditEngulfment, Not Gas: Two Fatal Case Studies
Level 3
Two operators drowned despite passing gas tests because they were engulfed by solids in a confined space.
Approved for renewal creditSigns and Tags: What They Legally Mean
Level 1
Operators sometimes confuse signs and tags or misuse lockout/tagout tags, leading to safety risks and regulatory problems.
Approved for renewal creditConfined Space Rescue: Why Rescuers Die Too
Level 1
Many confined-space deaths are would-be rescuers who went in after the first victim.
Approved for renewal creditHarness, Anchor, Hook: What Fails and Why
Level 1
Falls from heights at wastewater plants often happen because of using the wrong harness, anchor, or lanyard, or missing key safety checks.
Approved for renewal creditLadders at a Plant: Portable, Fixed, and 2036
Level 1
Falls from ladders are a real risk at a plant, and fixed ladders come with a 2036 deadline.
Approved for renewal creditActivated sludge & biological treatment12
Activated Sludge: Advanced Process Control
Level 1
Troubles with treatment processes often come from misreading key indicators like sludge levels or oxygen readings, leading to wrong adjustments that hurt plant stability.
Approved for renewal creditTreatment Process Fundamentals
Level 1
One connected hour on how a plant works, from headworks and primary clarifiers through activated sludge, secondary clarifiers, nitrification and disinfection.
Approved for renewal creditRising Sludge or Bulking: Telling Them Apart
Level 1
Sludge floating on the clarifier can be rising sludge or bulking, and each needs the opposite fix.
Approved for renewal creditIntroduction to Wastewater: Sources, Treatment
Level 1
A plain-language starting point: where wastewater comes from, how a plant treats it, what a permit asks of the plant, and the basics of staying safe on the job.
Approved for renewal creditActivated Sludge 2: What Each Change Does
Level 2
Every activated sludge lever changes more than one thing at once.
Approved for renewal creditActivated Sludge Process Control
Level 1
An activated sludge plant is run with a handful of levers, and the common pitfalls show up in the effluent.
Approved for renewal creditActivated Sludge Modes: What Each One Buys
Level 2
Operators often face unexpected changes in plant performance when switching activated sludge modes without fully understanding each mode's impact.
Approved for renewal creditNitrification: Alkalinity, Cold and Sludge Age
Level 1
Nitrification is fragile, and three things commonly knock it out: alkalinity runs out, the water gets cold, or the sludge age is too short.
Approved for renewal creditReading Sludge Quality: The Five Control Tests
Level 2
Read one at a time, sludge test results can point you to the wrong lever.
Approved for renewal creditFilamentous Bulking: Cause, Cure and Mistakes
Level 1
When filaments take over, settling fails and solids head for the effluent.
Approved for renewal creditWasting Rate, Sludge Age and the F/M Lever
Level 1
Operators often struggle to balance wasting rate, sludge age, and the food-to-microorganism (F/M) ratio, leading to unstable or inefficient treatment.
Approved for renewal creditChemical Phosphorus Removal: Feed, Floc and Sludge
Level 1
Too little metal salt misses the phosphorus limit, and too much costs money and buries you in sludge.
Approved for renewal creditClarifiers & settling3
Clarifier Operation and Troubleshooting
Level 1
Clarifiers are where many effluent problems first show.
Approved for renewal creditClarifier Capacity: Four Ways to Overload It
Level 2
Secondary clarifiers can get overloaded in four different ways, each affecting sludge handling and effluent quality differently.
Approved for renewal creditSecondary Clarifier Blanket and RAS Control
Level 1
Let the blanket rise too high and solids go over the weir; pull it too low and the biology suffers.
Approved for renewal creditWet weather, collection & lift stations18
The Records That Win a Bypass or Upset Case
Level 3
Incorrect or incomplete records during bypass or upset events can lead to permit violations and costly penalties.
Approved for renewal creditHeadworks: What Gets Past Screens and Grit
Level 1
Rags and grit that slip past the headworks show up later as plugged pumps, worn equipment and lost tank volume.
Approved for renewal creditInfiltration or Inflow: Telling Them Apart
Level 1
Groundwater leaking in and stormwater pouring in look alike at the plant, but they behave differently and have different fixes.
Approved for renewal creditThe Lift Station Is a Flow Control, Not a Pipe
Level 1
In a storm a lift station decides how flow reaches the plant; it is not just a pipe.
Approved for renewal creditCalibrating the Plant Flow Meter: the Annual Job
Level 1
Flow meters can drift out of calibration over the year, causing inaccurate flow readings that affect plant compliance and performance.
Approved for renewal creditProtecting the Process Through a Peak Flow
Level 1
A peak flow can wash the biology out of your plant in hours, and it takes weeks to rebuild.
Approved for renewal creditThe Approach Is Part of the Calibration
Level 1
A flow meter can be calibrated and still read wrong if the channel leading to it is not right.
Approved for renewal creditWet Weather Operations for Treatment Operators
Level 1
The overview course for storm season: infiltration and inflow, peak flows at the headworks, protecting the biology, and staying in compliance through the surge.
Approved for renewal creditStorm Modes: What To Switch and When It Is Late
Level 1
Switching modes too late is one of the commonest storm mistakes.
Approved for renewal creditThe Baffle That Works and the One That Does Not
Level 1
Wet weather can overload clarifiers, causing solids to wash out and harm biological treatment.
Approved for renewal creditSolids in the Effluent: Which Failure Is It?
Level 1
Solids in the effluent during wet weather can come from several different failures, and each needs a different fix.
Approved for renewal creditThe Storm Variables That Are Not Flow
Level 2
Storms change more than flow, and the other variables can upset a plant too.
Approved for renewal creditThree Field Checks on a Weir or Flume
Level 1
A weir or flume can read wrong for reasons you can check in the field.
Approved for renewal creditWet Weather at the Headworks: Grit and Screens
Level 1
In a storm the headworks takes the hit first: screens blind and grit floods in.
Approved for renewal creditWriting the Wet Weather Operating Plan
Level 1
When the storm arrives is too late to decide who does what.
Approved for renewal creditThe Flow Number: Contact Time and the Storm DMR
Level 1
In a storm your flow reading and your disinfection contact time are the numbers most likely to be wrong.
Approved for renewal creditWhen a Lift Station Overflows or Must Be Bypassed
Level 1
Lift station overflows during wet weather often lead to costly mistakes and regulatory trouble.
Approved for renewal creditBypass and Upset: The Defence You Must Prove
Level 1
A bypass or upset is a violation unless you can prove the defense, and the proof is built before and during the event.
Approved for renewal creditPumps, electrical & energy11
The Peak You Pay For: Demand Charges
Level 2
High demand charges can make your plant's electricity bill spike unexpectedly, especially when pumps and motors start at the same time.
Approved for renewal creditPump Energy: Throttling, Heads and Clean Pipe
Level 1
Pumping more pressure than needed or throttling pumps the wrong way wastes energy and increases costs at wastewater plants.
Approved for renewal creditMotors, Nameplates and the Power Bill
Level 1
Motors run the plant's equipment, and they show up on the power bill.
Approved for renewal creditHead: What Your Pump Is Really Working Against
Level 1
Pumps often run inefficiently because operators don't fully understand the system pressure and losses they work against.
Approved for renewal creditMaintenance That Finds Faults, Not Just Grease
Level 1
Just greasing pumps and motors can miss early signs of trouble, leading to unexpected breakdowns and costly repairs.
Approved for renewal creditWho May Touch It: The Electrical Boundary
Level 1
Operators sometimes take on electrical tasks without knowing where the legal and safety lines are, risking injury or code violations.
Approved for renewal creditInsulation Testing: The Megger and the Trend
Level 1
Electric motors and cables can fail unexpectedly if insulation problems aren't spotted early.
Approved for renewal creditImpellers, Packing and the Pump That Fights You
Level 1
Pumps that run hot, leak, or wear out quickly often have the wrong impeller, bad packing care, or misaligned shafts and pipes.
Approved for renewal creditFind Your Own Peak: The Energy Survey
Level 2
Unexpected spikes in energy use can lead to high demand charges and wasted power at wastewater plants.
Approved for renewal creditCavitation, Suction Lift and Priming
Level 1
Pumps can suffer serious damage from cavitation, suction lift problems, or improper priming, leading to costly repairs and downtime.
Approved for renewal creditDrives and Alignment: Which Job Is Yours
Level 1
Mixing up close-coupled and split-shaft drives or mismanaging shear pins can cause unexpected pump failures and downtime.
Approved for renewal creditPermits, DMRs & compliance9
Reading Your NPDES Permit: What It Actually Asks
Level 1
The big-picture one: what your permit requires, in its numbers and its words, and how those requirements become your monthly DMR.
Approved for renewal creditReading Your NPDES Permit: Rows and Units
Level 1
The detailed one: the rows of limits, the units and averaging periods behind each number, and the load calculations, so the number you report is the number your permit means.
Approved for renewal creditRounding: The Step That Decides Compliance
Level 2
An effluent result can look compliant in a spreadsheet but become a violation when the DMR rounding rule or non-detect substitution is applied.
Approved for renewal creditDMR Arithmetic: Loads, Removal and the Flow Term
Level 1
Load and percent-removal calculations go wrong in the same few places every month.
Approved for renewal creditHow Illinois Proves a Violation: Averaging
Level 1
In Illinois, whether a result is a violation depends on the averaging period and the multiplier in your permit.
Approved for renewal creditThe 85% Removal Condition Nobody Reports
Level 1
An Illinois plant can meet its effluent limits and still miss the permit's 85% removal condition because nobody calculates it, especially during wet weather.
Approved for renewal creditSeasonal Disinfection and the Sample Count
Level 1
Seasonal disinfection and sampling rules in Illinois can cause confusion about when and how to meet bacterial limits, leading to compliance mistakes.
Approved for renewal creditLimits That Move: Seasons, Floors and Bands
Level 1
Some limits change with the season, some set a minimum, and some are a range.
Approved for renewal creditWhy Your Plant Has the Limits It Has
Level 1
Every limit in your permit has a reason behind it: the stream, your treatment train and your plant's classification.
Approved for renewal creditPretreatment4
Inspecting an Industrial User: What to Look At
Level 2
Industrial users sometimes discharge pollutants beyond permit limits, putting the plant at risk and causing potential violations.
Approved for renewal creditLocal Limits: The Headworks Calculation
Level 2
Plants sometimes face trouble controlling pollutants because local limits at the headworks aren't properly calculated or understood.
Approved for renewal creditThe Combined Wastestream Formula
Level 2
Misunderstanding how dilution and production limits work can cause permit violations in industrial pretreatment programs.
Approved for renewal creditWhen a User Claims Upset: Judging the Defence
Level 2
Industrial users sometimes claim upset or bypass defences to avoid penalties, but many of these claims don't meet federal rules.
Approved for renewal creditEmergency response & chemicals5
Can You Still Reach It? Shutoffs, Air and Intakes
Level 1
In a chemical release, an emergency plan only works if the shutoff can be reached, the air intakes don't pull the gas indoors, and the safety equipment isn't inside the hazard.
Approved for renewal creditChlorine Release: Detection, Kit and First Moves
Level 1
Chlorine leaks can pose serious dangers if not detected quickly or if emergency kits are misused, putting people and the plant at risk.
Approved for renewal creditStandby Power: Proved Under Load, or Not Proved
Level 1
A generator that starts on its weekly test can still fail when it has to carry the plant.
Approved for renewal creditChemical Delivery and Incompatible Storage
Level 1
A delivery put into the wrong tank, or incompatible chemicals stored side by side, can set off a dangerous reaction.
Approved for renewal creditSpill Response Without Causing a Second Release
Level 1
A rushed response to a chemical or sewage spill can cause a second, worse release.
Approved for renewal creditSolids handling & digestion3
Digester Gas: CO2, Burners and Stray Methane
Level 1
Poor gas quality, a neglected burner or methane where it should not be can each turn a digester into a hazard.
Approved for renewal creditDigester Souring: The Four Numbers and the Cure
Level 1
Digesters can sour without obvious signs, leading to inefficient gas production and costly downtime.
Approved for renewal creditDewatering: Choosing the Route, Reading the Belt
Level 1
Send sludge down the wrong dewatering route, or misread the belt press, and the plant pays for it.
Approved for renewal creditDisinfection4
Tracer Testing a Contact Tank: t10 and Baffling
Level 1
Operators often miss hydraulic problems like short-circuiting or slime buildup in contact tanks because they don't know how to run or read tracer tests.
Approved for renewal creditDisinfection 3: Judgement at Three Plants
Level 3
Disinfection isn't always straightforward - three real plants reveal how contact time, residual control, and permit limits can cause tricky decisions in daily operations.
Approved for renewal creditDisinfection CT: Contact Time Is Not Volume/Flow
Level 1
Tank volume divided by flow can overstate your real contact time, because water short-circuits through the tank.
Approved for renewal creditDisinfection 2: What the Dose Actually Buys
Level 2
Changing chlorine dose without understanding contact time and residual levels can lead to missed disinfection targets or wasted chemicals.
Approved for renewal creditLagoons, ponds & fixed film12
Lagoon Levers: What Each Change Costs
Level 2
Making changes in lagoon operations without knowing their effects can cause poor effluent, sludge build-up, or higher costs.
Approved for renewal creditTrickling Filters: What More Flow Buys and Costs
Level 2
Operators often face trouble when increasing flow through trickling filters without understanding how it affects recirculation, sludge, and effluent quality.
Approved for renewal creditPond Maintenance: Levees, Weeds and Burrows
Level 1
Weeds, burrowing animals and weak levees are behind many costly pond failures, and all three can be caught early.
Approved for renewal creditWorking Over Water: Jackets, Buoys and Rescue
Level 1
Operators working on lagoons often miss key safety rules about life jackets and rescue gear, leading to dangerous situations over water.
Approved for renewal creditThe Lagoon Round: Sludge Depth and the Bottle
Level 1
Operators often struggle with measuring lagoon sludge properly and missing key inspection steps that keep lagoons running smoothly and safely.
Approved for renewal creditPond Upsets: Low DO, Odor and Turnover
Level 1
Facultative ponds go wrong in predictable ways: oxygen crashes, odor and seasonal turnover.
Approved for renewal creditTrickling Filter Arm Speed and Recirculation
Level 1
Distributor arm speed and recirculation are the two main controls on a trickling filter.
Approved for renewal creditAfter the Filter: Clarifier, Chlorine and Sludge
Level 1
What comes after a trickling filter or RBC is not run like an activated sludge plant.
Approved for renewal creditLagoon Effluent: Flow, Coliform and Chemicals
Level 1
Lagoon effluent brings its own measuring problems.
Approved for renewal creditLagoons: What You Control and What You Inherit
Level 1
In a lagoon system, much of what matters was decided when it was built.
Approved for renewal creditFilter Media: Depth, Grading and BOD Credit
Level 1
For trickling filters and RBCs, the media decides how much treatment you get credit for.
Approved for renewal creditRBCs: Shaft Weight, Film Control and Failure
Level 1
A rotating biological contactor fails when the biofilm gets too heavy for the shaft.
Approved for renewal creditLab, sampling & instruments10
What Each Bench Test Measures, and Its Traps
Level 1
Operators often run bench tests without fully understanding what each one measures or where errors commonly happen, leading to confusing or misleading results.
Approved for renewal creditWhat a Duplicate Can and Cannot Tell You
Level 2
Duplicates are a useful quality check, but they only tell you so much about your data.
Approved for renewal creditSystematic or Random: Reading a Meter's Errors
Level 1
Mistakes in flow meter readings can come from installation issues like blockage or corrosion, not just the instrument itself.
Approved for renewal creditGauges, Thermometers and Alarms You Can Trust
Level 1
Inaccurate gauges, thermometers, and alarms can lead to false readings and wrong maintenance decisions at the plant.
Approved for renewal creditChemical Hygiene: Which Rule Your Lab Is Under
Level 1
Wastewater lab workers often confuse OSHA's Chemical Hygiene standard with Hazard Communication rules, risking noncompliance and unsafe practices.
Approved for renewal creditDuplicates, Spikes and Blanks
Level 1
Mistakes in lab results often come from misunderstanding duplicates, spikes, and blanks used for quality control, leading to inaccurate data and permit problems.
Approved for renewal creditDefending a Number You Cannot Measure Again
Level 3
Sometimes critical instrument readings in the plant can't be repeated, raising questions about their accuracy and legal standing.
Approved for renewal creditWhy the Sample Is Wrong Before the Bench
Level 1
Samples taken incorrectly or handled wrong can lead to bad data, missed violations, and costly mistakes at the plant.
Approved for renewal creditThe Bench Sheet Is the Record
Level 1
Operators sometimes treat bench sheets and calibration records as informal notes, risking permit violations and data problems.
Approved for renewal creditCalibration Records and the Flows Nobody Logs
Level 1
Inspectors ask for calibration records, and the flows that never get logged quietly throw off your numbers.
Approved for renewal creditHydraulics & chemical dosing5
Reading Your Wastewater Plant's Design Basis
Level 1
Wastewater operators often confuse plant hydraulic capacities with process design limits, leading to poor compliance decisions.
Approved for renewal creditFlow Splitting: Why One Tank Fails First
Level 1
When parallel tanks get unequal flow, one fails while the others coast.
Approved for renewal creditHydraulic vs Organic Capacity
Level 1
A plant can be full on flow and have room on load, or the reverse.
Approved for renewal creditClarifier Weirs: Loading, Level and Blocks
Level 1
Uneven or blocked weirs let solids escape over one side of the clarifier.
Approved for renewal creditThe Four Design Flows and What Your Permit Uses
Level 1
Illinois defines four design flows, and your permit uses them in its compliance calculations.
Approved for renewal creditManagement & operator math6
Rounding for Compliance: One Rule, Three Errors
Level 1
Incorrect rounding and arithmetic errors can cause your compliance reports to show violations when there aren't any.
Approved for renewal creditThe Daily Round: What To Check and What To Log
Level 1
Operators often miss or misrecord key daily checks and lab data, risking plant performance and regulatory trouble.
Approved for renewal creditSOPs That Exist and SOPs That Get Used
Level 1
A plant can have a binder full of SOPs that nobody follows.
Approved for renewal creditWhy Small Plants Fail: The Resource Chain
Level 1
Small plants often fail not because of treatment problems but from missing resources and weak administrative support.
Approved for renewal creditRates, Replacement and the Missing Third Term
Level 1
Many plants struggle because their user fees don't cover replacement costs, putting future repairs at risk.
Approved for renewal creditWho Is In Charge: Coverage as a Permit Term
Level 1
Misunderstanding who must be on duty to meet the permit's operator-in-charge requirement can lead to compliance problems and violations.
Approved for renewal creditCybersecurity3
Cyber Duties Already in Your Emergency Plan
Level 1
Operators may miss or hesitate on cybersecurity steps already included in their plant's Emergency Response Plan, leaving the plant vulnerable during an incident.
Approved for renewal creditWhat Each Cyber Control Actually Stops
Level 2
Operators often don't know which cybersecurity controls actually protect their plant or how to spot when those controls fail.
Approved for renewal creditWhen the Control System Cannot Be Trusted
Level 1
Control system data can be wrong or misleading during failures or cyber incidents, putting plant safety at risk.
Approved for renewal creditComing soon in Illinois7
Primary Clarifiers: Withdrawal Rate and Septicity
Level 1
Pump sludge out of the primary too slowly and it turns septic; pump it too fast and you send water to the digester.
Approved — not yet released for enrollmentFire Extinguishers
Level 1
Many plants mix up who needs fire extinguisher training versus just basic education, leading to compliance problems and safety risks.
Approved — not yet released for enrollmentThe Sample Decides It: Bottles and Devices
Level 1
Using the wrong sample bottles or devices can mess up test results and lead to bad treatment decisions.
Approved — not yet released for enrollmentThe Operating Point: Reading a Pump Curve
Level 1
A pump does not run wherever you want it to; it runs where its curve meets your system's.
Approved — not yet released for enrollmentRespirators: Hazard Assessment and IDLH
Level 1
The wrong respirator in the wrong atmosphere is worse than none, because it feels safe.
Approved — not yet released for enrollmentIllinois Effluent Standards: Which Rung, Why
Level 1
Illinois sets your effluent limits by a ladder of standards tied to your plant's class.
Approved — not yet released for enrollmentWhy an Ammonia Limit Exists: pH and Temp
Level 1
Ammonia is far more toxic to fish when the water is warm and the pH is high, which is why your limit moves.
Approved — not yet released for enrollmentFor every state
Written so nothing in them changes from one state to the next.
Maintenance Chemicals: Grout, Paint and Fuel
Level 1
Workers sometimes handle grout, paint, or fuel without recognizing the chemical hazards or following proper safety rules, which can lead to exposure and regulatory trouble.
Approved for renewal creditRespond or Evacuate: The HAZWOPER Choice
Level 1
Confusion over when to handle hazardous spills in-house or evacuate can put employees at risk and violate safety rules.
Approved for renewal creditThe Peak You Pay For: Demand Charges
Level 2
High demand charges can make your plant's electricity bill spike unexpectedly, especially when pumps and motors start at the same time.
Approved for renewal creditLagoon Levers: What Each Change Costs
Level 2
Making changes in lagoon operations without knowing their effects can cause poor effluent, sludge build-up, or higher costs.
Approved for renewal creditPump Energy: Throttling, Heads and Clean Pipe
Level 1
Pumping more pressure than needed or throttling pumps the wrong way wastes energy and increases costs at wastewater plants.
Approved for renewal creditMotors, Nameplates and the Power Bill
Level 1
Motors run the plant's equipment, and they show up on the power bill.
Approved for renewal creditTracer Testing a Contact Tank: t10 and Baffling
Level 1
Operators often miss hydraulic problems like short-circuiting or slime buildup in contact tanks because they don't know how to run or read tracer tests.
Approved for renewal creditHazard Communication at a Treatment Plant
Level 1
Every chemical on site comes with a label and a safety data sheet you're expected to understand.
Approved for renewal creditActivated Sludge: Advanced Process Control
Level 1
Troubles with treatment processes often come from misreading key indicators like sludge levels or oxygen readings, leading to wrong adjustments that hurt plant stability.
Approved for renewal creditThe Records That Win a Bypass or Upset Case
Level 3
Incorrect or incomplete records during bypass or upset events can lead to permit violations and costly penalties.
Approved for renewal creditTreatment Process Fundamentals
Level 1
One connected hour on how a plant works, from headworks and primary clarifiers through activated sludge, secondary clarifiers, nitrification and disinfection.
Approved for renewal creditHeadworks: What Gets Past Screens and Grit
Level 1
Rags and grit that slip past the headworks show up later as plugged pumps, worn equipment and lost tank volume.
Approved for renewal creditTrickling Filters: What More Flow Buys and Costs
Level 2
Operators often face trouble when increasing flow through trickling filters without understanding how it affects recirculation, sludge, and effluent quality.
Approved for renewal creditClarifier Operation and Troubleshooting
Level 1
Clarifiers are where many effluent problems first show.
Approved for renewal creditRounding for Compliance: One Rule, Three Errors
Level 1
Incorrect rounding and arithmetic errors can cause your compliance reports to show violations when there aren't any.
Approved for renewal creditRising Sludge or Bulking: Telling Them Apart
Level 1
Sludge floating on the clarifier can be rising sludge or bulking, and each needs the opposite fix.
Approved for renewal creditHead: What Your Pump Is Really Working Against
Level 1
Pumps often run inefficiently because operators don't fully understand the system pressure and losses they work against.
Approved for renewal creditCan You Still Reach It? Shutoffs, Air and Intakes
Level 1
In a chemical release, an emergency plan only works if the shutoff can be reached, the air intakes don't pull the gas indoors, and the safety equipment isn't inside the hazard.
Approved for renewal creditWelding and Hot Work: The Fume You Did Not Choose
Level 1
Welding and hot work can create invisible fumes and gases like ozone or phosgene that put workers at risk and cause safety problems at the plant.
Approved for renewal creditClassifying Trench Soil: Two Tests, Five Traps
Level 1
Misclassifying trench soil can lead to unsafe excavations and trench collapses, risking serious injury and plant damage.
Approved for renewal creditPermit-Required Confined Space Entry
Level 1
Wet wells, manholes and tanks are where operators die, and too often it is the person who goes in to help.
Approved for renewal creditDigester Gas: CO2, Burners and Stray Methane
Level 1
Poor gas quality, a neglected burner or methane where it should not be can each turn a digester into a hazard.
Approved for renewal creditIntroduction to Wastewater: Sources, Treatment
Level 1
A plain-language starting point: where wastewater comes from, how a plant treats it, what a permit asks of the plant, and the basics of staying safe on the job.
Approved for renewal creditThe Daily Round: What To Check and What To Log
Level 1
Operators often miss or misrecord key daily checks and lab data, risking plant performance and regulatory trouble.
Approved for renewal creditWastewater Operator Safety
Level 1
The hazards that kill operators: confined spaces, hydrogen sulfide and other bad atmospheres, stored energy, chemicals and biological exposure.
Approved for renewal creditActivated Sludge 2: What Each Change Does
Level 2
Every activated sludge lever changes more than one thing at once.
Approved for renewal creditInspecting an Industrial User: What to Look At
Level 2
Industrial users sometimes discharge pollutants beyond permit limits, putting the plant at risk and causing potential violations.
Approved for renewal creditMaintenance That Finds Faults, Not Just Grease
Level 1
Just greasing pumps and motors can miss early signs of trouble, leading to unexpected breakdowns and costly repairs.
Approved for renewal creditHazard Assessment: What Changes the Answer
Level 2
Choosing the wrong respiratory protection or PPE in confined spaces can put operators at serious risk, especially with changing conditions and H2S levels.
Approved for renewal creditWhat Each Bench Test Measures, and Its Traps
Level 1
Operators often run bench tests without fully understanding what each one measures or where errors commonly happen, leading to confusing or misleading results.
Approved for renewal creditWhat a Duplicate Can and Cannot Tell You
Level 2
Duplicates are a useful quality check, but they only tell you so much about your data.
Approved for renewal creditInfiltration or Inflow: Telling Them Apart
Level 1
Groundwater leaking in and stormwater pouring in look alike at the plant, but they behave differently and have different fixes.
Approved for renewal creditThe Bench Lab: Which OSHA Rule Covers It
Level 1
Wastewater bench labs often miss key OSHA rules that lead to unsafe conditions and compliance issues.
Approved for renewal creditLockout/Tagout for Pumps, Blowers and Mixers
Level 1
A pump, blower or mixer that restarts or turns over during maintenance can kill.
Approved for renewal creditCyber Duties Already in Your Emergency Plan
Level 1
Operators may miss or hesitate on cybersecurity steps already included in their plant's Emergency Response Plan, leaving the plant vulnerable during an incident.
Approved for renewal creditFalls Into Tanks: The Trigger Is Not Four Feet
Level 1
Many operators think fall protection rules apply only above four feet, but falls near tanks and hazardous equipment can be just as dangerous.
Approved for renewal creditWhat Each Cyber Control Actually Stops
Level 2
Operators often don't know which cybersecurity controls actually protect their plant or how to spot when those controls fail.
Approved for renewal creditPond Maintenance: Levees, Weeds and Burrows
Level 1
Weeds, burrowing animals and weak levees are behind many costly pond failures, and all three can be caught early.
Approved for renewal creditThe Safety Training Calendar: What Repeats
Level 1
Operators often miss or confuse safety training deadlines, risking noncompliance and unsafe work conditions.
Approved for renewal creditThe Lift Station Is a Flow Control, Not a Pipe
Level 1
In a storm a lift station decides how flow reaches the plant; it is not just a pipe.
Approved for renewal creditCalibrating the Plant Flow Meter: the Annual Job
Level 1
Flow meters can drift out of calibration over the year, causing inaccurate flow readings that affect plant compliance and performance.
Approved for renewal creditTrench Safety for Plant Crews: The 5-Foot Myth
Level 1
Many crews believe trenches under 5 feet deep don't need special safety measures, but this can lead to dangerous accidents.
Approved for renewal creditWho May Touch It: The Electrical Boundary
Level 1
Operators sometimes take on electrical tasks without knowing where the legal and safety lines are, risking injury or code violations.
Approved for renewal creditInsulation Testing: The Megger and the Trend
Level 1
Electric motors and cables can fail unexpectedly if insulation problems aren't spotted early.
Approved for renewal creditSystematic or Random: Reading a Meter's Errors
Level 1
Mistakes in flow meter readings can come from installation issues like blockage or corrosion, not just the instrument itself.
Approved for renewal creditClarifier Capacity: Four Ways to Overload It
Level 2
Secondary clarifiers can get overloaded in four different ways, each affecting sludge handling and effluent quality differently.
Approved for renewal creditLocal Limits: The Headworks Calculation
Level 2
Plants sometimes face trouble controlling pollutants because local limits at the headworks aren't properly calculated or understood.
Approved for renewal creditActivated Sludge Process Control
Level 1
An activated sludge plant is run with a handful of levers, and the common pitfalls show up in the effluent.
Approved for renewal creditDisinfection 3: Judgement at Three Plants
Level 3
Disinfection isn't always straightforward - three real plants reveal how contact time, residual control, and permit limits can cause tricky decisions in daily operations.
Approved for renewal creditBloodborne Pathogens: What the Rule Covers
Level 1
Does the bloodborne pathogens rule apply to wastewater work? This hour covers where OSHA's standard applies and where it does not, how biological…
Approved for renewal creditActivated Sludge Modes: What Each One Buys
Level 2
Operators often face unexpected changes in plant performance when switching activated sludge modes without fully understanding each mode's impact.
Approved for renewal creditDigester Souring: The Four Numbers and the Cure
Level 1
Digesters can sour without obvious signs, leading to inefficient gas production and costly downtime.
Approved for renewal creditWorking Over Water: Jackets, Buoys and Rescue
Level 1
Operators working on lagoons often miss key safety rules about life jackets and rescue gear, leading to dangerous situations over water.
Approved for renewal creditProtecting the Process Through a Peak Flow
Level 1
A peak flow can wash the biology out of your plant in hours, and it takes weeks to rebuild.
Approved for renewal creditThe Approach Is Part of the Calibration
Level 1
A flow meter can be calibrated and still read wrong if the channel leading to it is not right.
Approved for renewal creditGauges, Thermometers and Alarms You Can Trust
Level 1
Inaccurate gauges, thermometers, and alarms can lead to false readings and wrong maintenance decisions at the plant.
Approved for renewal creditChemical Hygiene: Which Rule Your Lab Is Under
Level 1
Wastewater lab workers often confuse OSHA's Chemical Hygiene standard with Hazard Communication rules, risking noncompliance and unsafe practices.
Approved for renewal creditChlorine Release: Detection, Kit and First Moves
Level 1
Chlorine leaks can pose serious dangers if not detected quickly or if emergency kits are misused, putting people and the plant at risk.
Approved for renewal creditStandby Power: Proved Under Load, or Not Proved
Level 1
A generator that starts on its weekly test can still fail when it has to carry the plant.
Approved for renewal creditImpellers, Packing and the Pump That Fights You
Level 1
Pumps that run hot, leak, or wear out quickly often have the wrong impeller, bad packing care, or misaligned shafts and pipes.
Approved for renewal creditHydrogen Sulfide: Four Numbers, One Ceiling
Level 1
Hydrogen sulfide has several exposure limits, and mixing them up can put an operator in danger.
Approved for renewal creditNitrification: Alkalinity, Cold and Sludge Age
Level 1
Nitrification is fragile, and three things commonly knock it out: alkalinity runs out, the water gets cold, or the sludge age is too short.
Approved for renewal creditWet Weather Operations for Treatment Operators
Level 1
The overview course for storm season: infiltration and inflow, peak flows at the headworks, protecting the biology, and staying in compliance through the surge.
Approved for renewal creditDisinfection CT: Contact Time Is Not Volume/Flow
Level 1
Tank volume divided by flow can overstate your real contact time, because water short-circuits through the tank.
Approved for renewal creditReading Your Wastewater Plant's Design Basis
Level 1
Wastewater operators often confuse plant hydraulic capacities with process design limits, leading to poor compliance decisions.
Approved for renewal creditFind Your Own Peak: The Energy Survey
Level 2
Unexpected spikes in energy use can lead to high demand charges and wasted power at wastewater plants.
Approved for renewal creditStorm Modes: What To Switch and When It Is Late
Level 1
Switching modes too late is one of the commonest storm mistakes.
Approved for renewal creditChemical Delivery and Incompatible Storage
Level 1
A delivery put into the wrong tank, or incompatible chemicals stored side by side, can set off a dangerous reaction.
Approved for renewal creditCavitation, Suction Lift and Priming
Level 1
Pumps can suffer serious damage from cavitation, suction lift problems, or improper priming, leading to costly repairs and downtime.
Approved for renewal creditThe Lagoon Round: Sludge Depth and the Bottle
Level 1
Operators often struggle with measuring lagoon sludge properly and missing key inspection steps that keep lagoons running smoothly and safely.
Approved for renewal creditEngulfment, Not Gas: Two Fatal Case Studies
Level 3
Two operators drowned despite passing gas tests because they were engulfed by solids in a confined space.
Approved for renewal creditThe Baffle That Works and the One That Does Not
Level 1
Wet weather can overload clarifiers, causing solids to wash out and harm biological treatment.
Approved for renewal creditSolids in the Effluent: Which Failure Is It?
Level 1
Solids in the effluent during wet weather can come from several different failures, and each needs a different fix.
Approved for renewal creditSOPs That Exist and SOPs That Get Used
Level 1
A plant can have a binder full of SOPs that nobody follows.
Approved for renewal creditReading Your NPDES Permit: What It Actually Asks
Level 1
The big-picture one: what your permit requires, in its numbers and its words, and how those requirements become your monthly DMR.
Approved for renewal creditReading Sludge Quality: The Five Control Tests
Level 2
Read one at a time, sludge test results can point you to the wrong lever.
Approved for renewal creditDisinfection 2: What the Dose Actually Buys
Level 2
Changing chlorine dose without understanding contact time and residual levels can lead to missed disinfection targets or wasted chemicals.
Approved for renewal creditFlow Splitting: Why One Tank Fails First
Level 1
When parallel tanks get unequal flow, one fails while the others coast.
Approved for renewal creditThe Combined Wastestream Formula
Level 2
Misunderstanding how dilution and production limits work can cause permit violations in industrial pretreatment programs.
Approved for renewal creditThe Storm Variables That Are Not Flow
Level 2
Storms change more than flow, and the other variables can upset a plant too.
Approved for renewal creditDrives and Alignment: Which Job Is Yours
Level 1
Mixing up close-coupled and split-shaft drives or mismanaging shear pins can cause unexpected pump failures and downtime.
Approved for renewal creditSigns and Tags: What They Legally Mean
Level 1
Operators sometimes confuse signs and tags or misuse lockout/tagout tags, leading to safety risks and regulatory problems.
Approved for renewal creditDuplicates, Spikes and Blanks
Level 1
Mistakes in lab results often come from misunderstanding duplicates, spikes, and blanks used for quality control, leading to inaccurate data and permit problems.
Approved for renewal creditConfined Space Rescue: Why Rescuers Die Too
Level 1
Many confined-space deaths are would-be rescuers who went in after the first victim.
Approved for renewal creditThree Field Checks on a Weir or Flume
Level 1
A weir or flume can read wrong for reasons you can check in the field.
Approved for renewal creditPond Upsets: Low DO, Odor and Turnover
Level 1
Facultative ponds go wrong in predictable ways: oxygen crashes, odor and seasonal turnover.
Approved for renewal creditFilamentous Bulking: Cause, Cure and Mistakes
Level 1
When filaments take over, settling fails and solids head for the effluent.
Approved for renewal creditWet Weather at the Headworks: Grit and Screens
Level 1
In a storm the headworks takes the hit first: screens blind and grit floods in.
Approved for renewal creditWriting the Wet Weather Operating Plan
Level 1
When the storm arrives is too late to decide who does what.
Approved for renewal creditWasting Rate, Sludge Age and the F/M Lever
Level 1
Operators often struggle to balance wasting rate, sludge age, and the food-to-microorganism (F/M) ratio, leading to unstable or inefficient treatment.
Approved for renewal creditWhen a User Claims Upset: Judging the Defence
Level 2
Industrial users sometimes claim upset or bypass defences to avoid penalties, but many of these claims don't meet federal rules.
Approved for renewal creditHarness, Anchor, Hook: What Fails and Why
Level 1
Falls from heights at wastewater plants often happen because of using the wrong harness, anchor, or lanyard, or missing key safety checks.
Approved for renewal creditDewatering: Choosing the Route, Reading the Belt
Level 1
Send sludge down the wrong dewatering route, or misread the belt press, and the plant pays for it.
Approved for renewal creditWhen the Control System Cannot Be Trusted
Level 1
Control system data can be wrong or misleading during failures or cyber incidents, putting plant safety at risk.
Approved for renewal creditLadders at a Plant: Portable, Fixed, and 2036
Level 1
Falls from ladders are a real risk at a plant, and fixed ladders come with a 2036 deadline.
Approved for renewal creditIllinois rules & reporting
These courses teach Illinois's own regulations, so they are offered for Illinois only.
Trickling Filter Arm Speed and Recirculation
Level 1
Distributor arm speed and recirculation are the two main controls on a trickling filter.
Approved for renewal creditReading Your NPDES Permit: Rows and Units
Level 1
The detailed one: the rows of limits, the units and averaging periods behind each number, and the load calculations, so the number you report is the number your permit means.
Approved for renewal creditHydraulic vs Organic Capacity
Level 1
A plant can be full on flow and have room on load, or the reverse.
Approved for renewal creditRounding: The Step That Decides Compliance
Level 2
An effluent result can look compliant in a spreadsheet but become a violation when the DMR rounding rule or non-detect substitution is applied.
Approved for renewal creditDMR Arithmetic: Loads, Removal and the Flow Term
Level 1
Load and percent-removal calculations go wrong in the same few places every month.
Approved for renewal creditWhy Small Plants Fail: The Resource Chain
Level 1
Small plants often fail not because of treatment problems but from missing resources and weak administrative support.
Approved for renewal creditDefending a Number You Cannot Measure Again
Level 3
Sometimes critical instrument readings in the plant can't be repeated, raising questions about their accuracy and legal standing.
Approved for renewal creditClarifier Weirs: Loading, Level and Blocks
Level 1
Uneven or blocked weirs let solids escape over one side of the clarifier.
Approved for renewal creditRates, Replacement and the Missing Third Term
Level 1
Many plants struggle because their user fees don't cover replacement costs, putting future repairs at risk.
Approved for renewal creditThe Flow Number: Contact Time and the Storm DMR
Level 1
In a storm your flow reading and your disinfection contact time are the numbers most likely to be wrong.
Approved for renewal creditAfter the Filter: Clarifier, Chlorine and Sludge
Level 1
What comes after a trickling filter or RBC is not run like an activated sludge plant.
Approved for renewal creditChemical Phosphorus Removal: Feed, Floc and Sludge
Level 1
Too little metal salt misses the phosphorus limit, and too much costs money and buries you in sludge.
Approved for renewal creditHow Illinois Proves a Violation: Averaging
Level 1
In Illinois, whether a result is a violation depends on the averaging period and the multiplier in your permit.
Approved for renewal creditWhy the Sample Is Wrong Before the Bench
Level 1
Samples taken incorrectly or handled wrong can lead to bad data, missed violations, and costly mistakes at the plant.
Approved for renewal creditSecondary Clarifier Blanket and RAS Control
Level 1
Let the blanket rise too high and solids go over the weir; pull it too low and the biology suffers.
Approved for renewal creditThe 85% Removal Condition Nobody Reports
Level 1
An Illinois plant can meet its effluent limits and still miss the permit's 85% removal condition because nobody calculates it, especially during wet weather.
Approved for renewal creditSeasonal Disinfection and the Sample Count
Level 1
Seasonal disinfection and sampling rules in Illinois can cause confusion about when and how to meet bacterial limits, leading to compliance mistakes.
Approved for renewal creditThe Bench Sheet Is the Record
Level 1
Operators sometimes treat bench sheets and calibration records as informal notes, risking permit violations and data problems.
Approved for renewal creditSpill Response Without Causing a Second Release
Level 1
A rushed response to a chemical or sewage spill can cause a second, worse release.
Approved for renewal creditLimits That Move: Seasons, Floors and Bands
Level 1
Some limits change with the season, some set a minimum, and some are a range.
Approved for renewal creditWhen a Lift Station Overflows or Must Be Bypassed
Level 1
Lift station overflows during wet weather often lead to costly mistakes and regulatory trouble.
Approved for renewal creditThe Four Design Flows and What Your Permit Uses
Level 1
Illinois defines four design flows, and your permit uses them in its compliance calculations.
Approved for renewal creditLagoon Effluent: Flow, Coliform and Chemicals
Level 1
Lagoon effluent brings its own measuring problems.
Approved for renewal creditLagoons: What You Control and What You Inherit
Level 1
In a lagoon system, much of what matters was decided when it was built.
Approved for renewal creditFilter Media: Depth, Grading and BOD Credit
Level 1
For trickling filters and RBCs, the media decides how much treatment you get credit for.
Approved for renewal creditWhy Your Plant Has the Limits It Has
Level 1
Every limit in your permit has a reason behind it: the stream, your treatment train and your plant's classification.
Approved for renewal creditWho Is In Charge: Coverage as a Permit Term
Level 1
Misunderstanding who must be on duty to meet the permit's operator-in-charge requirement can lead to compliance problems and violations.
Approved for renewal creditRBCs: Shaft Weight, Film Control and Failure
Level 1
A rotating biological contactor fails when the biofilm gets too heavy for the shaft.
Approved for renewal creditCalibration Records and the Flows Nobody Logs
Level 1
Inspectors ask for calibration records, and the flows that never get logged quietly throw off your numbers.
Approved for renewal creditBypass and Upset: The Defence You Must Prove
Level 1
A bypass or upset is a violation unless you can prove the defense, and the proof is built before and during the event.
Approved for renewal creditComing soon in Illinois
Built and waiting on a final review or the state's approval. Ask to be told the day one opens.
Primary Clarifiers: Withdrawal Rate and Septicity
Level 1
Pump sludge out of the primary too slowly and it turns septic; pump it too fast and you send water to the digester.
Approved — not yet released for enrollmentFire Extinguishers
Level 1
Many plants mix up who needs fire extinguisher training versus just basic education, leading to compliance problems and safety risks.
Approved — not yet released for enrollmentThe Sample Decides It: Bottles and Devices
Level 1
Using the wrong sample bottles or devices can mess up test results and lead to bad treatment decisions.
Approved — not yet released for enrollmentThe Operating Point: Reading a Pump Curve
Level 1
A pump does not run wherever you want it to; it runs where its curve meets your system's.
Approved — not yet released for enrollmentRespirators: Hazard Assessment and IDLH
Level 1
The wrong respirator in the wrong atmosphere is worse than none, because it feels safe.
Approved — not yet released for enrollmentIllinois Effluent Standards: Which Rung, Why
Level 1
Illinois sets your effluent limits by a ladder of standards tied to your plant's class.
Approved — not yet released for enrollmentWhy an Ammonia Limit Exists: pH and Temp
Level 1
Ammonia is far more toxic to fish when the water is warm and the pH is high, which is why your limit moves.
Approved — not yet released for enrollmentNot seeing what you need?
Tell us the subject and we will add it to the list. What operators ask for is how we decide what to build next.